Monitor statistics generated at: 20082841726 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC NaN 0.00 0 4.75 5.25 0 0 power supply -5.2VDC NaN 0.00 0 -5.50 -4.75 0 0 power supply +28VDC NaN 0.00 0 26.60 29.40 0 0 power supply +15VDC NaN 0.00 0 14.50 15.50 0 0 power supply -15VDC NaN 0.00 0 -15.50 -14.50 0 0 spacek supply +5VDC NaN 0.00 0 4.75 5.25 0 0 spacek supply +12VDC NaN 0.00 0 11.75 12.25 0 0 2.1 GHzPhaseLock (TTL) NaN 0.00 0 0.90 1.10 0 0 15.4 GHzPhaseLock (TTL) NaN 0.00 0 0.90 1.10 0 0 SW fault (TTL) NaN 0.00 0 0.90 1.10 0 0 Pulse fault (TTL) NaN 0.00 0 0.90 1.10 0 0 temperature (indoor) 57.93 NaN 1 5.00 35.00 0 1 temperature (warm load) 53.71 NaN 1 -50.00 50.00 0 1 temperature (RF plate) 55.18 NaN 1 -50.00 50.00 0 1 UPSInputVoltage 79.93 69.22 3 114.00 126.00 2 1 UPSOutputVoltage 80.20 69.46 3 114.00 126.00 2 1 UPSOutputCurrent 1.87 1.62 3 0.00 5.70 3 0 UPSBatteryVoltage 9.01 7.81 3 13.25 14.50 2 1 TransmittedRFPower 0.00 0.00 0 57.00 63.00 0 0 Transmitted RF Power History Past 10/100/1000 Hours: 62.09/ 61.44/ 51.93 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0