Monitor statistics generated at: 20082842200 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC NaN 0.00 0 4.75 5.25 0 0 power supply -5.2VDC NaN 0.00 0 -5.50 -4.75 0 0 power supply +28VDC NaN 0.00 0 26.60 29.40 0 0 power supply +15VDC NaN 0.00 0 14.50 15.50 0 0 power supply -15VDC NaN 0.00 0 -15.50 -14.50 0 0 spacek supply +5VDC NaN 0.00 0 4.75 5.25 0 0 spacek supply +12VDC NaN 0.00 0 11.75 12.25 0 0 2.1 GHzPhaseLock (TTL) NaN 0.00 0 0.90 1.10 0 0 15.4 GHzPhaseLock (TTL) NaN 0.00 0 0.90 1.10 0 0 SW fault (TTL) NaN 0.00 0 0.90 1.10 0 0 Pulse fault (TTL) NaN 0.00 0 0.90 1.10 0 0 temperature (indoor) 57.23 0.33 2 5.00 35.00 0 2 temperature (warm load) 52.98 0.35 2 -50.00 50.00 0 2 temperature (RF plate) 51.51 1.73 2 -50.00 50.00 0 2 UPSInputVoltage 106.84 40.07 9 114.00 126.00 8 1 UPSOutputVoltage 106.94 40.10 9 114.00 126.00 8 1 UPSOutputCurrent 2.54 0.96 9 0.00 5.70 9 0 UPSBatteryVoltage 12.02 4.51 9 13.25 14.50 8 1 TransmittedRFPower 62.10 -Inf 273 57.00 63.00 74 199 Transmitted RF Power History Past 10/100/1000 Hours: 62.10/ 61.46/ 51.94 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/1