Monitor statistics generated at: 20082850100 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 3 4.75 5.25 3 0 power supply -5.2VDC -5.24 0.00 3 -5.50 -4.75 3 0 power supply +28VDC 27.93 0.00 3 26.60 29.40 3 0 power supply +15VDC 15.22 0.03 3 14.50 15.50 3 0 power supply -15VDC -15.20 0.03 3 -15.50 -14.50 3 0 spacek supply +5VDC 5.01 0.00 3 4.75 5.25 3 0 spacek supply +12VDC 12.01 0.00 3 11.75 12.25 3 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 3 0.90 1.10 3 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 3 0.90 1.10 3 0 SW fault (TTL) 1.00 0.00 3 0.90 1.10 3 0 Pulse fault (TTL) 1.00 0.00 3 0.90 1.10 3 0 temperature (indoor) 58.60 0.74 9 5.00 35.00 0 9 temperature (warm load) 53.87 0.65 9 -50.00 50.00 0 9 temperature (RF plate) 53.93 1.01 9 -50.00 50.00 0 9 UPSInputVoltage 117.14 19.52 38 114.00 126.00 37 1 UPSOutputVoltage 117.18 19.52 38 114.00 126.00 37 1 UPSOutputCurrent 2.78 0.47 38 0.00 5.70 38 0 UPSBatteryVoltage 13.17 2.19 38 13.25 14.50 37 1 TransmittedRFPower 62.10 37.35 1144 57.00 63.00 796 348 Transmitted RF Power History Past 10/100/1000 Hours: 62.10/ 61.47/ 51.95 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/1/0 Monitor statistics generated at: 20082850100 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 NaN 1 4.75 5.25 1 0 power supply -5.2VDC -5.24 NaN 1 -5.50 -4.75 1 0 power supply +28VDC 27.93 NaN 1 26.60 29.40 1 0 power supply +15VDC 15.19 NaN 1 14.50 15.50 1 0 power supply -15VDC -15.23 NaN 1 -15.50 -14.50 1 0 spacek supply +5VDC 5.00 NaN 1 4.75 5.25 1 0 spacek supply +12VDC 11.96 NaN 1 11.75 12.25 1 0 2.1 GHzPhaseLock (TTL) 1.00 NaN 1 0.90 1.10 1 0 15.4 GHzPhaseLock (TTL) 1.00 NaN 1 0.90 1.10 1 0 SW fault (TTL) 1.00 NaN 1 0.90 1.10 1 0 Pulse fault (TTL) 1.00 NaN 1 0.90 1.10 1 0 temperature (indoor) 57.93 NaN 1 5.00 35.00 0 1 temperature (warm load) 53.71 NaN 1 -50.00 50.00 0 1 temperature (RF plate) 55.66 NaN 1 -50.00 50.00 0 1 UPSInputVoltage 120.65 0.49 2 114.00 126.00 2 0 UPSOutputVoltage 120.25 0.07 2 114.00 126.00 2 0 UPSOutputCurrent 2.90 0.00 2 0.00 5.70 2 0 UPSBatteryVoltage 12.68 1.20 2 13.25 14.50 1 1 TransmittedRFPower 62.10 37.35 1144 57.00 63.00 796 348 Transmitted RF Power History Past 10/100/1000 Hours: 62.10/ 61.47/ 51.95 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0