Monitor statistics generated at: 20082851800 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 5 4.75 5.25 5 0 power supply -5.2VDC -5.24 0.00 5 -5.50 -4.75 5 0 power supply +28VDC 27.92 0.02 5 26.60 29.40 5 0 power supply +15VDC 15.19 0.00 5 14.50 15.50 5 0 power supply -15VDC -15.23 0.00 5 -15.50 -14.50 5 0 spacek supply +5VDC 5.01 0.00 5 4.75 5.25 5 0 spacek supply +12VDC 12.01 0.00 5 11.75 12.25 5 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 5 0.90 1.10 5 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 5 0.90 1.10 5 0 SW fault (TTL) 1.00 0.00 5 0.90 1.10 5 0 Pulse fault (TTL) 1.00 0.00 5 0.90 1.10 5 0 temperature (indoor) 59.10 0.64 17 5.00 35.00 0 17 temperature (warm load) 54.60 0.52 17 -50.00 50.00 0 17 temperature (RF plate) 56.67 1.61 17 -50.00 50.00 0 17 UPSInputVoltage 118.28 14.45 69 114.00 126.00 68 1 UPSOutputVoltage 118.58 14.49 69 114.00 126.00 68 1 UPSOutputCurrent 2.84 0.35 69 0.00 5.70 69 0 UPSBatteryVoltage 13.33 1.63 69 13.25 14.50 68 1 TransmittedRFPower 62.16 41.64 2063 57.00 63.00 1828 235 Transmitted RF Power History Past 10/100/1000 Hours: 62.11/ 61.65/ 52.09 TWTA attempted restarts (5 min thru 55 min) =0/0/1/0/0/0