Monitor statistics generated at: 20082941100 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 6 4.75 5.25 6 0 power supply -5.2VDC -5.24 0.00 6 -5.50 -4.75 6 0 power supply +28VDC 27.93 0.00 6 26.60 29.40 6 0 power supply +15VDC 15.19 0.00 6 14.50 15.50 6 0 power supply -15VDC -15.22 0.03 6 -15.50 -14.50 6 0 spacek supply +5VDC 5.01 0.00 6 4.75 5.25 6 0 spacek supply +12VDC 12.00 0.02 6 11.75 12.25 6 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 6 0.90 1.10 6 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 6 0.90 1.10 6 0 SW fault (TTL) 1.00 0.00 6 0.90 1.10 6 0 Pulse fault (TTL) 1.00 0.00 6 0.90 1.10 6 0 temperature (indoor) 59.30 0.66 20 5.00 35.00 0 20 temperature (warm load) 54.52 0.76 20 -50.00 50.00 0 20 temperature (RF plate) 58.40 0.89 20 -50.00 50.00 0 20 UPSInputVoltage 120.09 0.23 81 114.00 126.00 81 0 UPSOutputVoltage 120.70 0.14 81 114.00 126.00 81 0 UPSOutputCurrent 2.74 0.14 81 0.00 5.70 81 0 UPSBatteryVoltage 13.52 0.01 81 13.25 14.50 81 0 TransmittedRFPower 62.14 42.30 2430 57.00 63.00 2350 80 Transmitted RF Power History Past 10/100/1000 Hours: 62.11/ 62.14/ 52.51 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0