Monitor statistics generated at: 20082960907 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 2 4.75 5.25 2 0 power supply -5.2VDC -5.25 0.00 2 -5.50 -4.75 2 0 power supply +28VDC 27.93 0.00 2 26.60 29.40 2 0 power supply +15VDC 15.19 0.00 2 14.50 15.50 2 0 power supply -15VDC -15.23 0.00 2 -15.50 -14.50 2 0 spacek supply +5VDC 5.01 0.00 2 4.75 5.25 2 0 spacek supply +12VDC 11.99 0.03 2 11.75 12.25 2 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 2 0.90 1.10 2 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 2 0.90 1.10 2 0 SW fault (TTL) 1.00 0.00 2 0.90 1.10 2 0 Pulse fault (TTL) 1.00 0.00 2 0.90 1.10 2 0 temperature (indoor) 59.79 0.66 4 5.00 35.00 0 4 temperature (warm load) 54.93 1.02 4 -50.00 50.00 0 4 temperature (RF plate) 60.18 0.61 4 -50.00 50.00 0 4 UPSInputVoltage 120.19 0.06 15 114.00 126.00 15 0 UPSOutputVoltage 120.65 0.11 15 114.00 126.00 15 0 UPSOutputCurrent 2.88 0.06 15 0.00 5.70 15 0 UPSBatteryVoltage 13.53 0.01 15 13.25 14.50 15 0 TransmittedRFPower 62.19 28.81 3600 57.00 63.00 3599 1 Transmitted RF Power History Past 10/100/1000 Hours: 62.19/ 62.13/ 52.95 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0