Monitor statistics generated at: 20082991900 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 2 4.75 5.25 2 0 power supply -5.2VDC -5.24 0.00 2 -5.50 -4.75 2 0 power supply +28VDC 27.93 0.00 2 26.60 29.40 2 0 power supply +15VDC 15.19 0.00 2 14.50 15.50 2 0 power supply -15VDC -15.23 0.00 2 -15.50 -14.50 2 0 spacek supply +5VDC 5.00 0.00 2 4.75 5.25 2 0 spacek supply +12VDC 12.01 0.00 2 11.75 12.25 2 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 2 0.90 1.10 2 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 2 0.90 1.10 2 0 SW fault (TTL) 1.00 0.00 2 0.90 1.10 2 0 Pulse fault (TTL) 1.00 0.00 2 0.90 1.10 2 0 temperature (indoor) 68.93 23.58 7 5.00 35.00 0 7 temperature (warm load) 86.15 80.22 7 -50.00 50.00 0 7 temperature (RF plate) 87.19 69.86 7 -50.00 50.00 0 7 UPSInputVoltage 120.02 0.19 28 114.00 126.00 28 0 UPSOutputVoltage 120.60 0.11 28 114.00 126.00 28 0 UPSOutputCurrent 2.88 0.04 28 0.00 5.70 28 0 UPSBatteryVoltage 13.52 0.01 28 13.25 14.50 28 0 TransmittedRFPower 62.27 30.55 822 57.00 63.00 819 3 Transmitted RF Power History Past 10/100/1000 Hours: 62.27/ 62.24/ 53.92 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0