Monitor statistics generated at: 20083182100 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 4 4.75 5.25 4 0 power supply -5.2VDC -5.25 0.00 4 -5.50 -4.75 4 0 power supply +28VDC 27.93 0.00 4 26.60 29.40 4 0 power supply +15VDC 15.19 0.00 4 14.50 15.50 4 0 power supply -15VDC -15.23 0.00 4 -15.50 -14.50 4 0 spacek supply +5VDC 5.01 0.00 4 4.75 5.25 4 0 spacek supply +12VDC 12.01 0.00 4 11.75 12.25 4 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 4 0.90 1.10 4 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 4 0.90 1.10 4 0 SW fault (TTL) 1.00 0.00 4 0.90 1.10 4 0 Pulse fault (TTL) 1.00 0.00 4 0.90 1.10 4 0 temperature (indoor) 59.93 0.77 13 5.00 35.00 0 13 temperature (warm load) 55.14 0.86 13 -50.00 50.00 0 13 temperature (RF plate) 61.71 0.71 13 -50.00 50.00 0 13 UPSInputVoltage 117.81 16.49 53 114.00 126.00 52 1 UPSOutputVoltage 118.25 16.56 53 114.00 126.00 52 1 UPSOutputCurrent 2.81 0.40 53 0.00 5.70 53 0 UPSBatteryVoltage 13.26 1.86 53 13.25 14.50 52 1 TransmittedRFPower 62.27 42.58 1592 57.00 63.00 1525 67 Transmitted RF Power History Past 10/100/1000 Hours: 62.27/ 62.27/ 56.80 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0