Monitor statistics generated at: 20083260000 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 13 4.75 5.25 13 0 power supply -5.2VDC -5.25 0.00 13 -5.50 -4.75 13 0 power supply +28VDC 27.93 0.00 13 26.60 29.40 13 0 power supply +15VDC 15.19 0.01 13 14.50 15.50 13 0 power supply -15VDC -15.23 0.00 13 -15.50 -14.50 13 0 spacek supply +5VDC 5.01 0.00 13 4.75 5.25 13 0 spacek supply +12VDC 12.01 0.00 13 11.75 12.25 13 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 13 0.90 1.10 13 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 13 0.90 1.10 13 0 SW fault (TTL) 1.00 0.00 13 0.90 1.10 13 0 Pulse fault (TTL) 1.00 0.00 13 0.90 1.10 13 0 temperature (indoor) 59.80 0.75 40 5.00 35.00 0 40 temperature (warm load) 54.87 1.13 40 -50.00 50.00 0 40 temperature (RF plate) 61.35 0.87 40 -50.00 50.00 0 40 UPSInputVoltage 119.98 0.25 162 114.00 126.00 162 0 UPSOutputVoltage 120.33 0.20 162 114.00 126.00 162 0 UPSOutputCurrent 2.89 0.06 162 0.00 5.70 162 0 UPSBatteryVoltage 13.52 0.01 162 13.25 14.50 162 0 TransmittedRFPower 62.21 44.17 4875 57.00 63.00 4779 96 Transmitted RF Power History Past 10/100/1000 Hours: 62.22/ 62.23/ 58.50 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0