Monitor statistics generated at: 20083280100 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 5 4.75 5.25 5 0 power supply -5.2VDC -5.25 0.00 5 -5.50 -4.75 5 0 power supply +28VDC 27.93 0.00 5 26.60 29.40 5 0 power supply +15VDC 15.19 0.00 5 14.50 15.50 5 0 power supply -15VDC -15.23 0.00 5 -15.50 -14.50 5 0 spacek supply +5VDC 5.01 0.01 5 4.75 5.25 5 0 spacek supply +12VDC 12.01 0.00 5 11.75 12.25 5 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 5 0.90 1.10 5 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 5 0.90 1.10 5 0 SW fault (TTL) 1.00 0.00 5 0.90 1.10 5 0 Pulse fault (TTL) 1.00 0.00 5 0.90 1.10 5 0 temperature (indoor) 59.89 0.85 13 5.00 35.00 0 13 temperature (warm load) 55.55 0.64 13 -50.00 50.00 0 13 temperature (RF plate) 62.24 2.32 13 -50.00 50.00 0 13 UPSInputVoltage 120.07 0.15 50 114.00 126.00 50 0 UPSOutputVoltage 120.53 0.11 50 114.00 126.00 50 0 UPSOutputCurrent 2.89 0.06 50 0.00 5.70 50 0 UPSBatteryVoltage 13.52 0.01 50 13.25 14.50 50 0 TransmittedRFPower 62.19 44.19 1483 57.00 63.00 1420 63 Transmitted RF Power History Past 10/100/1000 Hours: 62.20/ 62.21/ 59.06 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0