Monitor statistics generated at: 20083361900 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 12 4.75 5.25 12 0 power supply -5.2VDC -5.25 0.00 12 -5.50 -4.75 12 0 power supply +28VDC 27.93 0.00 12 26.60 29.40 12 0 power supply +15VDC 15.21 0.03 12 14.50 15.50 12 0 power supply -15VDC -15.23 0.00 12 -15.50 -14.50 12 0 spacek supply +5VDC 5.01 0.00 12 4.75 5.25 12 0 spacek supply +12VDC 12.01 0.00 12 11.75 12.25 12 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 12 0.90 1.10 12 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 12 0.90 1.10 12 0 SW fault (TTL) 1.00 0.00 12 0.90 1.10 12 0 Pulse fault (TTL) 1.00 0.00 12 0.90 1.10 12 0 temperature (indoor) 59.63 1.15 35 5.00 35.00 0 35 temperature (warm load) 54.38 1.38 35 -50.00 50.00 0 35 temperature (RF plate) 60.39 1.03 35 -50.00 50.00 0 35 UPSInputVoltage 120.26 0.12 139 114.00 126.00 139 0 UPSOutputVoltage 120.57 0.12 139 114.00 126.00 139 0 UPSOutputCurrent 2.84 0.05 139 0.00 5.70 139 0 UPSBatteryVoltage 13.52 0.01 139 13.25 14.50 139 0 TransmittedRFPower 62.27 44.25 4173 57.00 63.00 4014 159 Transmitted RF Power History Past 10/100/1000 Hours: 62.27/ 62.21/ 61.50 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0