Monitor statistics generated at: 20091891500 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.23 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.95 0.03 10 26.60 29.40 10 0 power supply +15VDC 15.24 0.02 10 14.50 15.50 10 0 power supply -15VDC -15.24 0.02 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.01 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.02 0.02 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 58.97 0.48 30 5.00 35.00 0 30 temperature (warm load) 54.48 0.46 30 -50.00 50.00 0 30 temperature (RF plate) 59.60 0.36 30 -50.00 50.00 0 30 UPSInputVoltage 118.86 0.38 120 114.00 126.00 120 0 UPSOutputVoltage 120.19 0.12 120 114.00 126.00 120 0 UPSOutputCurrent 2.87 0.06 120 0.00 5.70 120 0 UPSBatteryVoltage 13.52 0.01 120 13.25 14.50 120 0 TransmittedRFPower 62.09 44.87 3600 57.00 63.00 2708 892 Transmitted RF Power History Past 10/100/1000 Hours: 62.08/ 62.20/ 61.77 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0