Monitor statistics generated at: 20091930900 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.23 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.93 0.02 10 26.60 29.40 10 0 power supply +15VDC 15.23 0.00 10 14.50 15.50 10 0 power supply -15VDC -15.25 0.02 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.00 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.02 0.02 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 58.98 0.70 30 5.00 35.00 0 30 temperature (warm load) 53.50 0.74 30 -50.00 50.00 0 30 temperature (RF plate) 59.59 0.54 30 -50.00 50.00 0 30 UPSInputVoltage 119.91 0.34 120 114.00 126.00 120 0 UPSOutputVoltage 120.46 0.13 120 114.00 126.00 120 0 UPSOutputCurrent 2.86 0.06 120 0.00 5.70 120 0 UPSBatteryVoltage 13.52 0.01 120 13.25 14.50 120 0 TransmittedRFPower 62.12 45.17 3600 57.00 63.00 3006 594 Transmitted RF Power History Past 10/100/1000 Hours: 62.14/ 62.16/ 62.10 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0