Monitor statistics generated at: 20091950200 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.23 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.94 0.02 10 26.60 29.40 10 0 power supply +15VDC 15.23 0.00 10 14.50 15.50 10 0 power supply -15VDC -15.24 0.02 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.00 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.01 0.00 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 59.06 0.74 30 5.00 35.00 0 30 temperature (warm load) 53.86 0.86 30 -50.00 50.00 0 30 temperature (RF plate) 59.59 0.92 30 -50.00 50.00 0 30 UPSInputVoltage 119.87 0.28 122 114.00 126.00 122 0 UPSOutputVoltage 120.46 0.14 122 114.00 126.00 122 0 UPSOutputCurrent 2.87 0.06 122 0.00 5.70 122 0 UPSBatteryVoltage 13.52 0.01 122 13.25 14.50 122 0 TransmittedRFPower 62.18 44.20 3617 57.00 63.00 3049 568 Transmitted RF Power History Past 10/100/1000 Hours: 62.17/ 62.13/ 62.16 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0