Monitor statistics generated at: 20091960900 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.23 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.93 0.02 10 26.60 29.40 10 0 power supply +15VDC 15.23 0.00 10 14.50 15.50 10 0 power supply -15VDC -15.24 0.02 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.00 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.01 0.00 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 59.10 0.72 30 5.00 35.00 0 30 temperature (warm load) 53.78 1.00 30 -50.00 50.00 0 30 temperature (RF plate) 59.80 0.64 30 -50.00 50.00 0 30 UPSInputVoltage 119.90 0.32 121 114.00 126.00 121 0 UPSOutputVoltage 120.47 0.14 121 114.00 126.00 121 0 UPSOutputCurrent 2.86 0.06 121 0.00 5.70 121 0 UPSBatteryVoltage 13.52 0.01 121 13.25 14.50 121 0 TransmittedRFPower 62.17 45.21 3604 57.00 63.00 3013 591 Transmitted RF Power History Past 10/100/1000 Hours: 62.18/ 62.15/ 62.21 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0