Monitor statistics generated at: 20091980500 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.23 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.93 0.02 10 26.60 29.40 10 0 power supply +15VDC 15.23 0.00 10 14.50 15.50 10 0 power supply -15VDC -15.25 0.03 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.00 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.01 0.00 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 59.21 0.77 30 5.00 35.00 0 30 temperature (warm load) 53.55 0.71 30 -50.00 50.00 0 30 temperature (RF plate) 59.20 0.94 30 -50.00 50.00 0 30 UPSInputVoltage 119.09 0.44 120 114.00 126.00 120 0 UPSOutputVoltage 120.35 0.23 120 114.00 126.00 120 0 UPSOutputCurrent 2.87 0.06 120 0.00 5.70 120 0 UPSBatteryVoltage 13.52 0.01 120 13.25 14.50 120 0 TransmittedRFPower 62.11 43.69 3600 57.00 63.00 3051 549 Transmitted RF Power History Past 10/100/1000 Hours: 62.14/ 62.16/ 62.21 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0