Monitor statistics generated at: 20091981500 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.03 0.00 10 4.75 5.25 10 0 power supply -5.2VDC -5.23 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 27.92 0.02 10 26.60 29.40 10 0 power supply +15VDC 15.23 0.02 10 14.50 15.50 10 0 power supply -15VDC -15.25 0.03 10 -15.50 -14.50 10 0 spacek supply +5VDC 5.00 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.02 0.02 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 59.68 0.63 30 5.00 35.00 0 30 temperature (warm load) 54.80 0.64 30 -50.00 50.00 0 30 temperature (RF plate) 60.03 0.50 30 -50.00 50.00 0 30 UPSInputVoltage 119.60 0.32 121 114.00 126.00 121 0 UPSOutputVoltage 120.42 0.13 121 114.00 126.00 121 0 UPSOutputCurrent 2.88 0.06 121 0.00 5.70 121 0 UPSBatteryVoltage 13.52 0.00 121 13.25 14.50 121 0 TransmittedRFPower 62.11 45.17 3603 57.00 63.00 2975 628 Transmitted RF Power History Past 10/100/1000 Hours: 62.11/ 62.16/ 62.21 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0